RECENT PROJECTS

Beachfront Multi-Story Building Evaluation, Palm Beach Shores FL


Coastal exposure assessment of a beachfront multi-story building, documenting chloride-driven corrosion, spalling, and envelope deterioration, and setting the scope for restoration.

SI

THRESHOLD INSPECTOR

Location

Palm Beach Shores, Palm Beach County, FL

STRUCTURE TYPE

Beachfront multi-story residential

our role

Evaluating Structural Engineer

Continuous coastal exposure on the Atlantic side


The building is located directly along the oceanfront in Palm Beach Shores, where reinforced concrete components are subjected to prolonged exposure to salt-laden air, wind-driven rain, and other coastal environmental conditions. Although the association had completed localized surface and finish repairs over the years, a comprehensive engineering evaluation of the underlying structural components had not been performed. As deterioration became more apparent, the association needed a clearer understanding of the condition and extent of concrete and reinforcement deterioration throughout the building.

The Problem

What We Were Retained to Evaluate


Decades of exposure to salt-laden air and wind-driven rain had contributed to deterioration at slab edges, railing embedments, columns, and other reinforced concrete components. Cracking, spalling, and corrosion-related staining were observed throughout portions of the building, raising concerns regarding the condition of the underlying reinforcement and concrete. The owner required an engineering evaluation to distinguish superficial and finish-related distress from deterioration affecting the integrity and structural performance of the building components.

THE ENGINEERING RESPONSE

How We Approached It


We evaluated the structure floor by floor, performing concrete sounding, documenting areas of distress and deterioration, and measuring concrete cover and reinforcement section loss at representative locations. Observed conditions were then correlated with the building’s original structural framing drawings to understand their location and significance within the structural system. This approach allowed us to distinguish localized surface deterioration from conditions affecting reinforcement, structural components, and their load-carrying performance.

Scope of Work

What the Engagement Included


  • Floor-by-floor structural condition assessment
  • Concrete sounding and delamination mapping at slab edges, columns, balconies, and railing embedments
  • Concrete cover and reinforcement section-loss measurements at representative locations
  • Review and correlation of observed conditions with available original structural drawings
  • Evaluation of superficial distress versus deterioration affecting structural components and performance
  • Identification and prioritization of concrete restoration and structural repair recommendations


Outcome

The structural condition assessment distinguished localized and surface-related deterioration from conditions requiring structural repair and established a prioritized restoration program based on the severity and structural significance of the observed deficiencies. Areas exhibiting more advanced concrete deterioration and reinforcement corrosion were identified for priority corrective action.


This project was delivered under our  Milestone Inspections / Structural Assessment. If you are facing something similar, we can tell you what the next step is before you commit to a scope.